1) Corrosion Problems: Generally water and dissolved pollutants can form highly corrosive acid solution. Wet Scrubbers are air pollution control devices for removing particles and gases from industrial exhaust stream. The diameter is 1.4 meters through the regular value. hi sir, When calculating or selecting an ejector design. From the design point of view, the design of the wet scrubber should be based on the exhaust gas volume, and the user can ask for 10,000 cubic meters. . Do that and I can review your work and point out any corrections if required. High-energy scrubber have pressure drops greater than 38.1 cm of water. The SSM was optimized as a hexagonal scrubber column with a diameter of 45.7 cm (18 in.) Calculation method of wet scrubber quotation. For dimensioning purposes, and to evaluate the workings of a scrubber, it is important to know how much liquid is required per m to realise the required residual emission. This technology is otherwise known as the water scrubbing technology. i noticed that the design was based on dry gas,the process i am working on produce a humid air(12%) how can i do the calculation taking account on that . Medical XPRT Scrubbers can also be designed to collect particulate matter and gaseous pollutants. Users can ask about 10,000 cubic meters per hour. Under normal temperature and pressure, the washing of PP material The scrubber is the most widely used, the price and cost of the scrubber are relatively low, and it is easy to process. Pdf, ejector design calculation xls, ejector design calculation software, steam. The company's first project in the early 1970's was a pilot venturi scrubbing system designed to remove oil and particulate from a contaminated air stream at an automotive manufacturing plant. The thickness of the scrubber bottom plate is 12mm, the thickness of the tower body is 8mm, and the wall thickness of the water tank is 10mm. Meters, the diameter is 1.4 meters through regularization. >> Gives high collection efficiency of solid & gaseous pollutant. Wet scrubbers control acid gases. What parts are included? Online product catalogs, news, articles, events, publications & more. hbbd``b` AX$X S"$ throat length is calculated to be 2.5 meters, isn't it on higher side a bit? Monroe Environmental specializes in wet and dry particulate collection for a wide variety of applications. What will be the general collection efficiency range for the venturi scrubbers? We have use Venturi scrubber in our project for Uranium project for high pressure vessel. Affect the wet scrubber quotation-product material. Venturi Scrubbers are primarily designed to control fine particulate matter (PM) from gaseous streams. The versatility of wet scrubber allows it to be built in numerous configurations. Before releasing waste gases that contain PM to the atmosphere, these gases are treated using venturi scrubbers to remove PM. hQk0W=E Important Considerations for H 2 S Scrubber Design There are many different possible designs for caustic scrubbers. p " t " t @ " p " t " x " | " | ` $ Perry (5) $ Calc m Eff'y / Evaporation Cost 4 Fabricated_Equipment_Index; A T As it is commonly known, syngas is an alternative for the coal and using syngas instead of the coal leads to 'clean energy' generation. Existing wet scrubber systems may meet the new standards with significant increase in power consumption. I want to design the ventury scrubber for biomass gasifier.Can you please send me some data sheets/pdf for that? Cyclone droplet eliminator (See KO pot folder for cyclone method). AddThis use cookies for handling links to social media. scrubber design xls, you can use related keywords : scrubber design xls Example: Select the wet scrubber model and give an accurate quotation. China Xicheng EP Ltd. After receiving the quotation for thewet scrubber, the customer often puts forward the quotation is too high, so many customers do not know the scrubber, but habitually give the conclusion that the price is too high, it seems that something is wrong, the technical team will pass the data Provide detailed basis and configuration of wet scrubber quotation. %PDF-1.7 % It results in lower capital costs and more flexibility. A generalized method for predicting venturi scrubber performance by equation (4-4) was developed in this study. The designed exhaust volume of the customer workshop is 10,000 cubic meters per hour, and the designed flow rate through the empty tower is 2 meters per second. The cake is a barrier with tortuous pores that trap particles as they travel through the cake.Gas temperatures up to about 500-F, with surges to about 550-F can be accommodated routinely in some configurations. Filler chooses 76 rosette, except The fog layer chooses 50 multi-faceted hollow sphere. ( ! The size of the scrubber is directly proportional to the capacity of the air volume. You can find almost nothing about HCl in another book, "Gas Purification Processes" by G. Nonhebel (Butterworths, 1972). The larger the wet scrubber, the more air volume it can handle. That way, we dont confuse issues within the same thread. Inlet gas features and dust properties (if present) are of more importance. ?_-;_-@_- 0.0% "$"#,##0 Cookies are only used in the browser to improve user experience. p @ " p @ ! The calculation method is to disassemble the plate. 1) Small space requirements: Scrubbers reduce the temp & volume of the unsaturated exhaust streams. Thanks for your great information,according to lt = 369.561*R^0.293 / vt^1.127 , I calculated throat length for a venturi Scrubber(Q=50000m3/hr , Q liquid=65m3/hr, vt=75m/sec), and result is about 3 meters. They are designed for applications requiring high removal efficiencies of submicron particles, between 0.5 and 5.0 micrometers in diameter. Wet lime scrubber . A wet scrubber system can be an advantage in controlling both of these emissions. hb```U@RAX#A(("pQm{ec|6,]x8}(4QA(w)G5kgYyk9'|#%a(p'Wqni6KVyF1n~txgJKijXZZX[DqZYXXjzhsGypZ$:>JT}%jODd>Jr}WvJ S)T(,.EY%`E@C'=B/,tODhV/aeq`` &&FA[Q(. l@ T ($2 1E!ve@ I am not sure if you can make theoretical calculations for throat velocity of an installed venturi scrubber. drop / m bed = 15 mmwc / m packing height = 147.1 total packing height = 3.2 m (including all packed beds) gas / vapour properties gas / air flow rate = 1000 kg/h or 0 = 0.2778 kg/s = 0 gas pressure at entry = 1.0000 atm gas temperature at ent = 30.00 = 303.00 gas / air The larger the scrubber, the more air volume it can handle, and vice versa. " " X a" X " \ " \ " H `@ @ ) ` @ ) `@ ) # `@ @ ` @ ` @ ` @ ` ` # p @ # p ` @ ` ` " The scrubber is selected and the price of the scrubber is given. Some of the water evaporates, especially if the process-air is hot, and disappear with the exhaust. mol), Suppose you are holding a container of gas, and the container has a fixed volume (i.e. i would also to know how to calculate all venturi dimension(Lconv,Ldiv,angles..) Thanks a lot. IHDR S * > sBIT3 sRGB pHYs + ~IDATx^u7$[Yzq#ll,(tlbWqB";4]P"y8Hae.REcH 3$*3y>s{~s|oqLn@YdYY24]g?_k/aok9 ];yWm=g.$aBupc? However, increasing the throat velocity beyond a certain value does not increase the collection efficiency. Wet Scrubbers are effective air pollution control devices for removing particles and/or gases from industrial exhaust streams.A Wet Scrubber operates by introducing the dirty gas stream with a scrubbing liquid - typically water. A liquid, in general water added with active chemicals adapted to the process, is sprayed in to the air flow. >> Ability to handle high temperature. a" \ " " 4""@ @ calculation sheet to make the calculation of this Venturi scrubber design, compare the results with that of a standard risk debugger. >> Provides Maximum pressure drop. 1. The larger the size (diameter and height), the more material and labor costs, and the higher the price of the wet scrubber. The scrubber quotation is based on the material and specifications. and could you please inform me about the reference of this formula. HlNH s$!LYp4n%w{j]7~K*v{]]}:wi?//}yoO/we]}{_>|>?}.x{x_:_^\76syff/ON?>_o`k}}}>rz3n{L1{L1{L1{LY}0 QX*@E$b HD$E&El4?F4DcXy,+cxX. endstream endobj startxref The scrubber materials mainly include PP polypropylene plastic, SS304 stainless steel, FRP glass fiber reinforced plastic, and carbon steel lining rubber. Having worked in fertilizers in the past (1975-81), we had elaborated process duty specs for HF / SiF4 scrubbers for bidders; but we had not used packed towers due to scales. really great article.means alot to me.Thanks Sir. These are common in various industrial applications which includes pollutant reduction at petroleum refineries, the large scale chemical processes, acid manufacturing plants and steel making steel. packing type = intallox saddles packing size = 25 mm packing moc = pp gas pr. Usually, the scrubber includes the tower body, packing, packing layers, integrated water tank, circulating pump, circulating water pipe, overflow pipe, drain pipe, water inlet ball valve, transparent liquid level pipe, the above is the configuration of conventional wet scrubber system. Thewet scrubbermaterials mainly include PP polypropylene plastic, SS304 stainless steel, FRP glass fiber reinforced plastic, carbon steel lined rubber, etc., under normal temperature and pressure, the PP material scrubber is used The most extensive, relatively low price cost, easy to process. The scrubber quotation is based on the tower diameter and height. The wet scrubber will handle dirty gas streams by mixing water or water solutions with the air or gas and transferring the solids or soluble gases to water. The size of the wet scrubber is proportional to its ability to handle the air volume. Calculation method of wet scrubber quotation Example: Select the wet scrubber model and give an accurate quotation. Your email address will not be published. Wet scrubber design excel sheet . Low Energy-High Efficiency Wet Scrubber Scrubbers can be classified by pressure drop as follows: 1. The scrubbing media used is water with 6% NaOH and the fluid to be scrubbed is a HC with a MW of 36.6 at 111 C and 1,000 ppm of HCl. Please read AddThis Privacy for more information. scrubbers ukdiss com, wet scrubber design calculation xls ezulwini com, gas scrubbers absorbtion columns venturi scrubbers, packed 1 / 3. scrubber design calculation, section 5 so and acid gas controls 2, venturi wet scrubbers sly inc, e journal of a fundamentals of renewable energy, wet Your email address will not be published. The typical wet scrubber system consists of a scrubbing vessel, a duct-work and fan system, a mist eliminator, a pumping, a spent scrubbing liquid treatment and an exhaust stack. After calculation, the diameter of the scrubber is 1.33 meters. Fig.2Design methodology for current investigation 3. But since you have responded to the OPs request, Ill go ahead and comment on your query. The most common mist eliminators are chevrons, mesh pads, and cyclones. 4. Wet scrubbers are usually the most appropriate air pollution-control device for collecting both, particulate and gas in a single system alone. d100)0 Thanks sir for the valuableinformation, however please guide me a bit further as I am designing a venturi scrubber for removal of particulate matter (218 mg/m3)from air at 1.6 m3/s. With the above data, the price of the scrubber is available. Hhi_group_integrated_report_2019.pdf - HHI- Scrubber for ships HHI developed a proprietary scrubber system (HHI-Scrubber) that meets the requirement under IMO's regulations. 2. The designed exhaust volume of the customer workshop is 10,000 cubic meters per hour, and the designed flow rate through the empty tower is 2 meters per second. Then gases are collected in the scrubbing liquid. 60. Jun 27 Industrial Equipments 17228 Views 24 Comments on Wet Scrubbers. The paper concerns the analytical research studies on . Engineering ToolBox - Resources, Tools and Basic Information for Engineering and Design of Technical Applications! >> Emission of minimum product through exhaust Great info you learn every day something new. >> Complete wetting of the product Add standard and customized parametric components - like flange beams, lumbers, piping, stairs and more - to your Sketchup model with the Engineering ToolBox - SketchUp Extension - enabled for use with the amazing, fun and free SketchUp Make and SketchUp Pro .Add the Engineering ToolBox extension to your SketchUp from the SketchUp Pro Sketchup Extension Warehouse! The gas is then washed with suitable liquid using spray nozzles. Based on the equation given in the blog article, you need the inputs to calculate the throat velocity. For calculations 1''venturi scrubber design xls scribd THERMAL ENERGY SYSTEMS Boiler waste gases utilizing coal, oil, biomass and liquid waste b. Scrubber design xls List of ebooks and manuels about Scrubber design xls Download our scrubber design xls eBooks for free and learn more about scrubber design xls. It is also used for the fume absorption hence it is very useful in fume extraction system. In atm 1 3 = 0.234499 m /s 29.45 Kg / Kmol If gas flow rate is given in m3/h Gas in = (m3/s) x 273 x pr. !fnsPZ*?N9+[%>sgn9N>OnT^Rw{L/zM0c}n 7p(>MU;H8vwoh}z7p-h The hot vapour/air comes from vessel which contains inert gases which is above 160 oC and sent to the Venturi for scrubber purpose. Required fields are marked *. Terms Design considerations and Calculations a)Volumetric concentration of SO 2 at inlet & outlet: Amount of SO 2 in flue gases= 0.3% of mole per mole of flue gas Y in = Input condition of SO 2 in flue gases Y in = 3 10-3 moles of SO 2 / mole of air Since, 1 mole of air (m)= 28.8 -10 3 kg Y Environmental XPRT is a global environmental industry marketplace and information resource. Agriculture XPRT 10. Detailed deriva- tion of the generalized method will be presented in the next chapter. 218 mmHg B. Many of you involved in engineering and design of wet scrubbing systems are already familiar with "Venturi Scrubbers". Download. m/h, how big is the scrubber, and what is the price of the wet scrubber? Required fields are marked *. Increase in Liquid-to-gas Ratios increases the collection efficiency. For example, a circular spray tower of 1.5-H4.2 (m) can handle air volume between 8000-10000, and is usually suitable for a space between 30-33 (the net height of the space is 3m, and the workshop needs to handle the air volume) ). Scrubber Wet Stack Design Guide. 1. Collection efficiency depends on the following factors: 1. The wet scrubber is determined according to the material and specifications of the exhaust gas scrubber. Some industrial processes need more cleaning than a single scrubber can provide. ! Design of the scrubber system Medium-energy scrubbers have pressure drops between 12.7 and 38.1 cm of water. The information which you shared was really helpful. CO 2) By product . The plane experiences a constant acceleration of 5.2 g's during the turn. Is there any way to measure throat velocity of an installed venturi scrubber? Large, proportional to the quoted price. advanced scrubber technologies - paramount fgd design and evaluation of a marine scrubber system, design of a primary off-gas scrubber system for a ferro. My project topic is "Design of Ventury scrubber for 1Mw biomass gasifier plant.". Secondly, another factor that affects the price is the size specifications. OR (ii) Increase the column diameter and repeat the above steps. Venturi Scrubber Design.xls - Free download as Excel Spreadsheet (.xls), PDF File (.pdf), Text File (.txt) or read online for free. mikropul wet scrubbers . Scrubbers can be classified by pressure drop as follows: 1. endstream endobj 11191 0 obj <>/Metadata 266 0 R/Outlines 371 0 R/Pages 11188 0 R/StructTreeRoot 3184 0 R/Type/Catalog/ViewerPreferences<>>> endobj 11192 0 obj <>/ExtGState<>/Font<>/ProcSet[/PDF/Text]>>/Rotate 0/StructParents 0/Tabs/S/Type/Page>> endobj 11193 0 obj <>stream 11190 0 obj <> endobj Vertical Packed Bed Scrubbers. ) _-* #,##0_-;\-* #,##0_-;_-* "-"? Maybe, the supplier of the complete venturi scrubber package would be able to provide some guidance. So vessel sizes, fans and ducts downstream are smaller than those of other control devices. Aerosol and gaseous pollutants in the air stream are removed by either absorption or chemical reactions with the water solution. ), Since larger flow quantities are at the bottom for an absorber, the diameter will be chosen to. Thanks for valuable information ragarding scrubber. Droplet size is dependent upon "Vr", while suited"Vt" depends upon droplet size (dl), so I have used iterative approach to converge at. But most of the scrubber operates over a wide range of pressure drops. Venturi scrubber calculator solving for estimated pressure drop given gas velocity and water to gas volume ratio. And all are designed to provide good contact between the liquid and polluted gas streams. The article is good enough to generate your own excel spreadsheet. The most commonly used acid gas controls are dry sorbent injection . equipped with three stages of PJ40 spray nozzles, spraying 1% (w/v) H2SO4 scrubbing liquid counter-current. PACKED SCRUBBER DESIGN HYDRAULIC DESIGN PROJECT Input data Process data Calculation type Find diameter Gas flow acfm 9100.00 38220.00 60.00 lb/h % flood Gas density pcf 0.07 Liquid flow USgpm 80.00 40000.00 500.00 lb/h Find % flood Liquid SG 1.00 tower diameter in 60.00 Liquid viscosity cP 0.80 Packing data RESULTS Type Tellerette Gas flow cfm . Venturi scrubber design calculation xls Built-in size (px) 344 x 292429 x 357514 x 422599 x 487DESCRIPTIONSizing the venturi scrubberTesto di Venturi Scrubber Design.xlsScrubberRaw Gas Venturi Scrubber Gas flow rate=110.00ACFMGas Temperature=400FPressure=1atm Humidity content=5%v/v Dry gas MW=29lb D.L.D. Do not allow panic, but try to be systematic and assimilate as much as possible. First, I would like to know under which operational conditions these equations are a decent fit since most are correlations. The diameter and height are calculated based on the total air volume and treatment concentration of the exhaust gas. document.getElementById( "ak_js_1" ).setAttribute( "value", ( new Date() ).getTime() ); document.getElementById( "ak_js_2" ).setAttribute( "value", ( new Date() ).getTime() ); E-mail: Leyte@china-xicheng.com Whatsapp:+8618028775826. The larger the size (diameter and height), the more materials and labor costs, and the higher the quotation. List of ebooks and manuels about Hcl gas scrubber design calculation. 0 0 \ ) 0.000000 0.00000 0.0000 However, I do not have much idea of any such on-line measurement. This chapter addresses the design and cost of wet scrubbers for control of PM 10 and PM 2.5. [4] A venturi scrubber employs a gradually ?_-;_-@_- 0.07 2 _-* #,##0.000_-;\-* #,##0.000_-;_-* "-"?? Your question is not clear. This process of saturation results in a change in volume, temperature and density. The higher the configuration, the higher the price of the scrubber. 5. WET SCRUBBER () . Typical Venturi Scrubber Design Parameters. After calculation, the diameter of the scrubber is 1.33 meters. . *1 ) T,j1fb~;1ps17wx)&p!Cr?XE iYB@zu_0N@:)&i@ & Medium-energy scrubbers have pressure drops between 12.7 and 38.1cm of water. . Calculation ln HETP = 0.8374366 HETP = 2.3104368ft = 0.7042211m For separations, less than 15 theoritical stages, a 20% design safety factor can be applied. The process of contacting the gas and liquid streams results in entrained droplets, which contain the contaminants or particulate matter. _ b  )dv7!RI c n[ )dv7!RIPNG Air volume calculation formula: equipment air volume = room volume (length width height) ventilation . The suitable packed bed provides large contact surface for the gases and liquid to mix and hence traps the pollutants. Scrubbers for particle collection are categorized by the gas-side pressure drop of the systems. and study "Hydrogen Chloride Absorption" in the Chapter "Water as an Absorbent". Spray towers are one of the more popular wet scrubber configurations used to bring waste gases in to contact with a sorbent designed to absorb and react with the SO 2 Venturi Scrubber Design.xls - Free download as Excel Spreadsheet (.xls), PDF File (.pdf), Text File (.txt) or read online for free. Inputs: It might definitely be possible to measure the actual throat velocity by providing some measurement instrument. SCRUBBER DESIGN (PACKED COLUMN) Prepared by : Column Tag No. INTEGRATED REPORT 2019 - Hyundai Heavy Industries.pdf. If gas A is 125 mmHg and gas B is 343 mmHg, what is the partial pressure of gas C? 3) Handles high-temperature, high-humidity gas streams: There is no temperature limit or condensation problem can occur in bag-houses. It is operated by introducing the dirty gas stream with a scrubbing liquid as water. I, myself, currently designing the venturi scrubber that is used to cleanse the syngas from tar and other fine dust. The higher the configuration, the higher the price of the scrubber. Design Equations For Venturi Scrubbers , scrubber designAs i am from Mechanical background,i have very less infoabout thisSo if you have previously done excel sheet/pdf of ventury scrubber design then that is very helpfull for me and that gives exact direction to my project work an existing tray or wet scrubber to a MMV scrubber design in . Clarification on the time allowed for this project of scrubber elementary design should have been given. The designs have become generally standardized, and units are manufactured by a large number of. These applications will - due to browser restrictions - send data between your browser and our server. 0 1218 mmHg C. 282 mmHg D. 468 mmHg. The object is then connected at the negative electrode of an electrolytic cell. You can target the Engineering ToolBox by using AdWords Managed Placements. Searching the Web, you can find more information, useful or not (e.g. Wet scrubber design calculation method The scrubber is selected and the price of the scrubber is given. For contaminant particles over 5 microns, the efficiency is >99%. ?_-;_-@_-4 + / _-* #,##0.00_-;\-* #,##0.00_-;_-* "-"? Collection efficiencies for wet scrubbers vary with the particle size distribution of . 345109621-scrubber-design-xls.xls - SCRUBBER DESIGN (PACKED COLUMN) Prepared by : Checked by : Date : # Input Data Packing type Packing size Packing | Course Hero 345109621-scrubber-design-xls.xls - SCRUBBER DESIGN (PACKED. Sheet 4 of 10 f HETP PREDICTION Norton's Correlation : ln HETP = n - 0.187 ln + 0.213 ln Applicable when, liquid phase surface tension > 4 dyne/cm & < 36 dyne/cm liquid viscosity > 0.08 cP . " for the equations) for equipment such important as wet scrubber. By using water eliminates the probability of explosions. Google use cookies for serving our ads and handling visitor statistics. @(pPo#q.1#~ZIW8.\O}"#>Q$?cyk5?P7ui_=@J?nCGi/bE)HQ=B =eW2S. %%EOF Save my name, email, and website in this browser for the next time I comment. Most of the energy used to operate the system appears as pressure drop across the bags and associated hardware and ducting. 4) Difficult product recovery: De-watering and drying of scrubber sludge makes recovery of dust very expensive and difficult for reuse. a wet scrubber may or may not be fully saturated, however they will exit the scrubber fully saturated. (See Section 5.2 Chapter 1 for information regarding wet scrubbers for acid gas control.) Course Hero is not sponsored or endorsed by any college or university. Venturi scrubbers are generally applied for controlling particulate matter and sulfur dioxide. Efficiency of Wet ScrubberProcess of wet scrubberwet scrubber design calculationwet scrubber technology, Your email address will not be published. 2. Evaporated water isreplaced by fresh water and chemicals. It is known that venturis have limited efficiency to absorb gases, but they are used for such in several cases - surprisingly with few output control as they lack proper understanding and dimensioning. Your email address will not be published. So what parts does the scrubber contain? tugas akhir ls 1336 kajian eksperimen penggunaan wet scrubber untuk mengurangi kadar sox dan nox pada motor diesel noventus hendyta. >> Fumes are also be absorbed For the . Instead of using water like the venturi-wet scrubbers, an alkaline solution, such as lime, is used. The quotation is about 25,000 yuan. A bio bed, which is an organic organism, require process air with as little dust as possible and temperature and humidity within certain limits. Water droplets are separated from the exhaust and re-circulated back to the water reservoir. 8.2.4.4 Wet scrubbers. (several editions and probably several publishers, 2nd edition is by Gulf publishing Co in 1974). The material costs incurred above, plus production costs and company profits are the quotations. If flooding is to be reduced, (i) Select larger packing size and repeat the above steps. For example, a circular wet scrubber of 1.5-H4.2 (m) can handle 8000-10000 air volumes, which is usually suitable for spaces between 30-33 (the net height of the space is 3m, and the workshop needs to handle the air volume) ). Low-energy scrubbers have pressure drops of less than 12.7 cm of water. I have taken "R = 1.2 m3/1000m3", "k = 0.15", "PM removal efficiency = 0.98 (fraction)". Venturi Scrubbers are sometimes used to absorb gases such as CO2 or SO3 for instance, but there is lack of literature on venturis as absorbers. The humidifying efficiency of the scrubber may be expressed as: h = (t1 - t2) / (t1 - tw) 100% (1). These books contain exercises and tutorials to improve your practical skills, at all levels! 3. Note! drop / m bed = 15 mmwc / m packing height = 147.1 total packing height = 3.2 m (including all packed beds) gas / vapour properties gas / air flow rate = 1000 kg/h or 0 = 0.2778 kg/s = 0 gas pressure at entry = 1.0000 atm gas temperature at ent = 30.00 = 303.00 gas / air 3. Generally for well designed scrubbers the collection efficiency is >98%. There are numerous types of wet scrubbers which remove both acid gas and PM. 0 0 _ ) ; [ R e d ] \ ( [ $ - 2 ] \ # , # # 0 . High-energy scrubber have pressure drops greater than 38.1cm of water. , , . A. In hard and decorative plating, the object to be plated is placed in a bath with a chromic acid solution.
Town Of Cotuit Ma Assessors Database, Frankincense And Myrrh Incense Spiritual Benefits, How Does Nike Communicate With Their Stakeholders, United Health Group Clinical Administrative Coordinator, Did Dee And Frank Have A Baby On Moesha, Houses For Rent In Fort Smith, Ar Pet Friendly, 97 Gone But Not Forgotten Portland Restaurants, Pat Ciarrocchi Wedding, Kid Friendly Things To Do In Oxford, Ms, Calgary Flames Ice Crew Roster,